I have noticed that the R13, 100 ohm, 3 watt resistor that is mounted longitudinally in front of the fan gets right hot. Maybe this is why it is placed in front of the fan. I can't keep my finger on it for any length of time when the amp has been on for a period of time in sideband or cw service. The K2/100-1 LCD readout shows 13.1 volts @ 480 ma in receive mode with the amp in the circuit. The readout shows 13.1 volts @ 680 to 700 ma with PTT engaged in SSB (no modulation). ALL options have been installed in this K2. If 200 ma flows through this resistor, I calculate this resistor is consuming 2.62 watts or more which means it is operating near its power rating. I just wanted to pass along this observation. Roy Morris W4WFB