On Sat, Sep 8, 2012 at 1:13 PM, Robert G. Strickland <[email protected]> wrote:
> Hello, all...
>
> I've just finished assembling my KPA500 and have a question about selecting
> the
> correct tap wire to set the operating voltage.
>
> My 220v line reads 231v no load, so I selected the yellow tap. The amp no load
> voltage is 71.7v. The transmitting voltage is 58v DC which is marginally low.
> If I
> select the red tap then I expect I'll be marginally high. If my choice is
> between
> marginally low and marginally high, which is the better choice? Thanks for
> comments.
Try the red tap. So long as the idle voltage is still under 85V, go with it.
73,
~iain / N6ML
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html