Properly assembled PowerPole connectors will not "get loose". The contacts are silver plated, so they should not corrode - even if they do, the wiping action when two APP connectors are plugged together will clean the contact area.
If your APP connectors are loose, they are not assembled right - make sure the blades are fully seated with the spring finger behind the tip of the contact blade. 73, Don W3FPR On 9/29/2012 1:59 PM, Lu Romero wrote: > Mike: > > Check your power connections to the K3, especially the > Anderson power poles. Sometimes they get "corroded" and > dont make good connection. Or they just get loose. This will > cause a momentary drop below 11 volts, and the K3 will shut > down. > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html