Properly assembled PowerPole connectors will not "get loose".  The 
contacts are silver plated, so they should not corrode - even if they 
do, the wiping action when two APP connectors are plugged together will 
clean the contact area.

If your APP connectors are loose, they are not assembled right - make 
sure the blades are fully seated with the spring finger behind the tip 
of the contact blade.

73,
Don W3FPR

On 9/29/2012 1:59 PM, Lu Romero wrote:
> Mike:
>
> Check your power connections to the K3, especially the
> Anderson power poles.  Sometimes they get "corroded" and
> dont make good connection. Or they just get loose. This will
> cause a momentary drop below 11 volts, and the K3 will shut
> down.
>