The PR6 is controlled by either the DIGOUT1 line in the ACC connector,
or with the jumper installed, it is connected with the RX ANT button
(not the PRE button).
So I don't see how you could use either the PRE button or the RX ANT button.
You could use the DIGOUT1 signal to operate a 5 volt relay (with a low
current draw coil) which in turn provides 12 volts to the preamp, but
your preamp would be active any time 2 meters is selected.
There is only 15 ma. available at the DIGOUT line, which means the
current draw must be low.
73,
Don W3FPR
On 2/16/2013 2:38 PM, Richard Thorpe wrote:
I have a 2 meter mast mounted preamp that is fed thus turned on by a bias tee
injecting 12V into the coax, can I control that preamp by switching that 12V
the same way the PR6 is controlled by the pre button on the K3 through the ACC
connector? Thank you.
R Thorpe K6CG
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html