Hi,
I'm having problems with my K3-100 with power out. If Power is 12 watts or
less
(100W pa not in use) and I adjust the power out then the power goes to the new
level with
no problem, as long as power requested is less than 12 watts.
When using the 100Watt PA if power is adjusted it will cause power to jump to
110 watts
for a second or less, then go to the requested power. This causes my KPA500 to
fault.
The problem is occuring with either the power knob or software from the
computer.
After the power stablizes at the new level then it is fine untill I change
power again.
This occurs in any mode. Any clues that can help me fix this?
SN is 5651, I built the K3 in August of 2011, it worked fine untill the last
month.
Thank you,
Gordon - N1MGO