Bought a used not working K2 and have fixed most problems, but, I have low
(MW) output on 15/17 and 12/10M. I have traced the problem to K6 latching in
the wrong position. When it is supposed to be latched for the 15/17M BPF it
is in the 12/10M position and latches in the 15/17 position when in 12/10M.
Is U1 the problem? It does switch states, and is positioned correctly, just
switches to the wrong BPF.
Thanks.........Dan WV8X
--
View this message in context:
http://elecraft.365791.n2.nabble.com/K6-relay-latching-wrong-tp7572787.html