I have completed my KRC2 to the point of the smoke test. No smoke ... I guess that is good.
When I power up, the LED lights (low), but no "short delay while the KRC2 performs diagnostics." The first test step, "Holding F1" , fails to produce 12 volts at the 60M source, or at any of ther terminals. I have done about 2 hours of visual inspection. Every diode is correctly oriented, as are all the ICs and the electrolytics. I am beginning to wonder if I have the voltage regulator in backward, though it looks exactly right. TGhe schematic says I should have +5 volts at C14 and +12 V at C13. I have the reverse. Before I try to unsolder U3, can someone confirm that those 2 caps are correctly labeled on the schematic? Also can someone describe the pin numbering for U3. It really looks like it is in there correctly. Also, the +5V end of D8 reads +5V (which should be right), but the -12V end of R12 is only -10.4V. Do these clues suggest anything? Tnx. 73 de Brian W3BW *Brian F. Wruble, C.F.A. *70 is the new 40.* * Mail: 1107 Key Plaza, PMB 447 Key West, FL 33040-4077 Summers: P.O.Box 57, 7400 Augustine Herman Highway, Georgetown, MD 21930 eFax 305.768.0278 ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html