This may be in archives but I could not find how to search archives on this list.
I am to the DC checks and 12 v in is greater than 1.6 megs - charging caps R36 to ground is OK 175 vs 150 min. BUt U12 dc reg output to ground is 422 ohms - says should be greater than 500 (but also says only slightly in some K3's) and U13 to ground is greater than 5K charging a cap. - They say greater than 125 ohms - big difference ??? Have checked and double checked connectors - no loose hardware etc . Like to hear comments before I go any farther. 73 Hank K7HP ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html