Hello Ross,

I had the same problem, witch is partial solved.
On my s/n #6552 the problem start with some suddenly loss of power on 10 
and also on 6 meter.
After some days, he fails completely the calibration.
The problem was one of the resistors on the LPA ( R-15, 2,7ohm 1/2 watt)
that change value to a bigger one.
The problem is solved for the low bands, but, on the high bands still have
random fails.
I have ordered new FET“s in order to replace the driver and maybe, the
finals of the LPA (RD06HHF1 and RD15HVF1).
I have intention to replace the RD06HHF1 for a RD06HVF1 as this one works
better on the 50 mhz region.

sorry for my bad English, but is not my native language.

73
Rodrigo
ct1bxt



--
View this message in context: 
http://elecraft.365791.n2.nabble.com/K3-5143-ERR-TXG-on-10m-6m-tp7576424p7576498.html
Sent from the Elecraft mailing list archive at Nabble.com.