once you have set CONFIG: TECH MD to ON then tap the [MENU] button to get out of CONFIG
now tap [DISP] (to make VFO B show various items, like voltage, current, PA temp, etc) turn VFO B knob until you see PLL 1 #.# or until you see PLL 2 #.# the #.# is actually the voltage reading example my PLL 1 shows 3.0 my PLL 2 shows 3.2 On 10/14/2013 8:16 PM, Jon Zaimes AA1K wrote:
Trying to debug two problems in one of my K3 receivers. Not sure if they might be related and just starting to delve into it. The main RX works fine for several minutes (although the sub RX seem to lack sensitivity) and then the main RX loses signals (although the background hiss seems constant) and I see ERR PL1. When I try the troubleshooting procedure in the manual: "VPLL out of range on band change (to view actual PLL voltage, set CONFIG: TECH MD to ON, then tap DISP and use VFO B to locate the PLL1 and PLL2 voltage displays)." This procedure goes OK but after I hit DISP the screen shoes "<OFF> SHOW TECH--MODE MENU ENTRIES, TAP 1/2 ..." but if I tap "1" or "2" it just shows "FFFF" at top of screen for either one. What does this mean? 73/Jon AA1K
-- GB & 73 K5OAI Sam Morgan ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html