Hello Brian: The probe is only an issue with the 100 watt amp installed.
The KSB2 manual calls for the probe to be reconnected in the first step of the Filter Alignment procedure. You need it for that. What's missing a note to remove the probe after the filter alignment is done if you have the 100 watt amp installed. That'll go in the pending change file. Thanks! 73 Ron AC7AC -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of Bryan Sent: Sunday, December 01, 2013 2:09 PM To: [email protected] Subject: [Elecraft] freq counter probe ? So, apparantly I should remove the probe from my K2/10 for normal operation ??? The manual is clear that it should be replaced after installing the KSB2. What's the recommendation here? 73, Bryan VE6HBS ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html