Ken,
You have the SWT19 and SWT27 in the wrong macros, causing the reassignment
to fail. Macro 1 assigns macro 1 to PF1 and macro 2 assigns macro 2 to PF1
rather than alternating so you get the desired toggling. Also, I always end
with the mn255. Try these:

1 ----  BW0280;SWH12;MN110;SWT27;SWH18;MN255;
2 ----  BW0005;SWT12;MN110;SWT19;SWH18;MN255;


73, Jim

-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Kenneth A.
Christiansen
Sent: Friday, December 27, 2013 5:19 AM
To: [email protected]
Subject: [Elecraft] Toggle PF1 in KX3

Hi from Ken W0CZ

I want to toggle between BW 2800 and BW 50 on my KX3. I wrote the following
macro lines and they work from the command line of the utility but do not
toggle when using the PF1 of the KX3.

1 ----  BW0280;SWH12;MN110;SWT19;SWH18;SWH09;
2 ----  BW0005;SWT12;MN110;SWT27;SWH18;SWH09;
I tried replacing  the SWH09; with MN255; but that did not work either. 

I have been using PF1 for line 1 and PF2 for line 2 but now my KXPA100 is on
the way and I want to use PF2 as a quick way to toggle between 5 watts and
100 watts. I suspect I will have the same problem when I try that macro.

73 and thanks for any help you can give.

Ken     W0CZ
[email protected]

Sent from my iPad=
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to