Good point Don!
That's why I use stainless steel hardware and ICE 602 copper/aluminum
anti-oxidant paste.
Glenn - KD0Q
On 12/30/2013 14:29, Don Wilhelm wrote:
Hmmm, An aluminum bar tied to a copper wire! Be aware that there will
be oxidation at the junction point due to dissimilar metals unless
special bonding is used to slow (but not stop) the oxidation.
Just something to bear in mind.
73,
Don W3FPR
On 12/30/2013 3:23 PM, KD0Q-Glenn wrote:
Everything in the shack is grounded to an aluminum bus bar across the
back of the operating table which is tied with #6 solid copper to the
same point as the tower and AC Main grounds.
Just for reference, the antenna is a 260ft OCF Inverted Vee at 75 ft
using a Balun Designs #4115ocf 4:1/Choke combination balun. Coax
shield is grounded at the top and bottom of the tower.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html