Hmmm ... I don't have a PA Temp problem, but ...
Occasionally, a tap or hold on a switch will cause some other action
other than the desired one. During NAQP SSB, I was running KPA500 off
but with the KAT500 [KAT3 bypassed]. The 500 was having some problems
on 160, so I bypassed it and was going to try the KAT3. When I held the
ATU switch to turn it on, the AGC shut off. First time that's ever
happened. My hearing is very bad [disappeared one night on a mountain
on the other side of the planet in my 20's], but believe me, it was LOUD
in the phones. Took about an hour for my ears to recover.
Is this symptomatic of the "Gold Pins Problem?"
K3 S/N 642, I built it and basically, it works perfectly except for this
anomaly. Next time I decide to use the KAT3, I'll take the cans off first.
73,
Fred K6DGW
- Northern California Contest Club
- CU in the 2014 Cal QSO Party 4-5 Oct 2014
- www.cqp.org
Anomaly [ah-NOM-ah-lee] n. A term used by NASA to indicate anything
from a burned out light bulb to the rocket landing pointy end down
outside Phoenix.
On 1/21/2014 9:36 AM, KENT TRIMBLE wrote:
To validate Wayne's suggestion . . .
K3 serial numbers 008 and 021 both exhibited this problem within two
years of their 2007 manufacture, and both were cured with the gold-pin
replacement fix.
Neither have exhibited any further misbehavior in the intervening years.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html