Thank you don for your points. First off the meter I am using has a maximum range of 40 M Ohms and I tested each point using the maximum range setting. The pins that indicated an "OF" reading were number 6, 7, 8, 14 and 16. All had a specified resistance of >100 k except for 16 which specified>1k. The amplifier U3 pin 5 specified >10k and amplifier u4 pin 6 specified >10k and >1k at pin 7. I appreciate all the input.
-- View this message in context: http://elecraft.365791.n2.nabble.com/K1-kit-not-showing-resistance-values-at-test-points-tp7584318p7584335.html Sent from the Elecraft mailing list archive at Nabble.com. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html