Are you entering these commands from the command tester?   It takes almost 50 
msec to wake up the microcontroller and several serial characters will arrive 
and are lost in that time. If you are entering commands from the command 
tester, it's better to turn off idle sleep. I have a command macro button set 
up with SL0;SL; to accomplish this.

The operate page works OK, right?

73 de Dick, K6KR



> On Apr 10, 2014, at 21:11, "Stan Gibbs, KR7C" <[email protected]> wrote:
> 
> With the new utility, I am still seeing incorrect responses from commands
> when the oscillator sleep is enabled.  The oscillator does start after one
> "an;" command, but the correct "AN1;" response does not occur until I send
> two more "an;" commands.
> 
> I would expect to see the correct response after the first "an;" command, as
> happens when the idle sleep is disabled.
> 
> 
> 
> 
> 
> -----
> 73, Stan - KR7C
> --
> View this message in context: 
> http://elecraft.365791.n2.nabble.com/KAT500-Utility-1-14-4-10-beta-test-version-available-on-our-FTP-site-tp7586987p7587005.html
> Sent from the Elecraft mailing list archive at Nabble.com.
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[email protected]
> 
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to [email protected]
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to