WA7SPY wrote
> MN,120; MP128;  (KX3 goes to CW Key 1 tip dot)
> 
> MN120; MP127; (KX3 goes to CW Key 1 HAND

The macros should be:
     MN120;MP000; (CW Key 1 tip=dot) bit 1 is CLEARED
and
     MN120;MP002; (CW Key 1 HAND) bit 1 is SET

You should only provide the bit value for the parameter selected by the MN;
command.

The best way to see the correct command is to use the utility to read the
value for whatever parameter you are interested in (in this case MN120)
after you set it to the value you want manually on the KX3.




-----
73, Stan - KR7C
--