Anderson Power Poles on the antenna jack?
On 6/29/2014 11:19 PM, Don Wilhelm wrote:
'Closing the barn door after the horse is gone' is not really helpful,
but I would advocate the use of Anderson Power Pole connectors with
fuses right at the power supply end of the power cord as prevention
for the future.
73,
Don W3FPR
On 6/29/2014 11:23 PM, Mike Lewis wrote:
Unfortunately this year in my excitement I carelessly installed the
DC block at the radio end BACKWARDS, sending the 13.8v from my 30
switched
supply right into the antenna jack.