Les wrote: >All the voltages and resistances check out except the anode of D9, >according to the manual, is supposed to be > 100k. I'm sure this is an >error, however, since the DC path to ground from that point goes through >three resistors and a choke totalling only about a couple K, which is what >I measure.
The manual calls for this to be greater than *100* ohms, not *100,000* ohms. A kit sold for 14 years is unlikely to have incorrect test point standards. :-) >I wish I had a layout view showing the bottom of the rf board to help. I have wished (for 14 years) for such PCB trace layouts. They are very appropriate for *ALL* kits. For some reason that has never been coherently explained, Elecraft has never supplied them. Tom/N0SS (SK) published photos of the PCB for the K1 years ago, but I do not think those are available any more, even at the remnant of his web site that is preserved by his ham club. Mike / KK5F ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected]