There is no Y cable needed for the RS-232 interface.  The RS-232
connector from the microHAM cable connects to the P3, the P3 connects
to the K3 via the Elecraft RS-232 cable supplied with the P3.

For best results configure the K3, P3, microHAM Router and your logging
software to operate and 38.400 bps.

*Remember* if you ever update firmware in the P3 or K3 connect the P3
directly to a hardware serial port or other USB to serial adapter.
Firmware updates are not supported through the microHAM interfaces due
to (1) polling by Router and (2) the need for a hardware reset in the
K3/P3.

The only Y cable needed is for the K3 ACC jack if you plan to operate
using FSK and/or use "PTT 2" (the second PTT output) from microKEYER.

73,

   ... Joe, W4TV


On 2014-08-23 12:34 PM, Orville wrote:
I am in the process of interfacing my new microKeyer II to my K3, P3 and
KPA500. I would like to correspond with someone that has an operational
system of this type. I believe I might need an additional Y-cable for the
RS-232 interface. Please respond off line to orville @ rubyglass.com.

Thanks,

Orville, K5VWW

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to