Fred,

What that means is that at 30 MHz, the amplitude is reduced by 3 dB. Usually, such a 'scope is useful for determining if there is a signal (assuming the 'scope has adequate vertical sensitivity), but should not be used to measure signal voltage with accuracy above about 10 MHz.

73,
Don W3FPR

On 8/23/2014 7:47 PM, Fred Townsend wrote:
Ron I have no comments about the KX1. However I do seem to recall the Tek 422 
has a 30 MHz bandwidth with a P6006 probe.

73
Fred, AE6QL