Hi, when working with the "DS response string", i found an easier and faster method to read the values from the equalizer.
If you select an AF-band in the RX/TX EQ menu, the set value appears briefly in the VFO-B display area. This value can be read out with the "DB command" then. The "SWTxx;" command and the "DB;" command must be carried out in quick succession. In the 'Elecraft K3 utility", you can for example run a macro"SWT34; DB;" and then receive the related response string. This note for general information. 73, Wolfgang DL2KI -- View this message in context: http://elecraft.365791.n2.nabble.com/K3-Eqalizer-settings-tp7593506p7593551.html Sent from the Elecraft mailing list archive at Nabble.com. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to arch...@mail-archive.com