Joe:

I suggest that you check the installation of C6 the 4.7 pf disc located on the very back of the board between L1 and L2. This capacitor shouold be installed so that there is an empty hole between the two leads. You actually install it in a spot for a jack that is installed if you install the 60Meter Module. Many guys install this capacitor on the two holes closest to the left edge of the board and when you do there is no coupling capacitor connected between L1 and L2. This might not be your problem but it is sure worth a quick look see.

73
Jim K4ZM