Hi Gary,

i had the same problem a few weeks ago.

Peter (DL2KI) by the German Elecraft service said that it might be a contact
problem.

I then removed the KAT3 and cleaned the contacts with a glass fibre brush.
Then everything was OK.

It could also be a contact problem on the connectors between front panel
module and main unit. The signals of the ATU are processed by the main
processor on the FP module.

73, Wolfgang
DL2KI



--
View this message in context: 
http://elecraft.365791.n2.nabble.com/Err-AT3-tp7594368p7594398.html
Sent from the Elecraft mailing list archive at Nabble.com.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]