On Fri,3/13/2015 10:45 AM, Richard Fjeld wrote:
I have found the center conductor on certain PL-259 plugs is slightly smaller 
than others. They make a marginal contact with the SO-239 socket. Sometimes 
intermittent. The trouble it causes can be hard to identify.

Junk connectors are a VERY common cause of problems. If the connector doesn't say Amphenol, it's almost certainly junk. An exception are the vintage connectors with MIL-spec numbers stamped into them. Amphenol's best solder-on PL-259 is 83-1SP.

73, Jim K9YC