Thanks Peter.

I do see the 90 degree phase difference and how it changes if I move above or below the test frequency. However the amplitude of just one, the ring conductor on the connector, decreases with increasing delta frequency. The amplitude of the tip remains steady regardless of the delta frequency.

I assume this isn't what I should be seeing. Now I need to figure out me next move as this seems to not be what the PX3 wants.

Does anyone know a reason the I and Q might be different amplitudes for the same signal?

Thanks.
John, kx4o

On 3/16/2015 8:38 PM, Peter Lambert wrote:
Hi John,

In this situation the amplitude of both the I and Q channels should be the
same and they should always be 90 degrees out of phase.

Peter VK4JD