There are other good solutions. Use the panels and charge controller to charge an outboard battery. Now you DO have enough for TX.

Genasun is the best, no RF noise, very efficient. They make different products that are designed for each type of battery chemistry, and for different power ratings. I use the GV-10 in my station.

http://genasun.com/products-store/mppt-solar-charge-controllers/

This SunForce is less efficient, no RF noise, but very inexpensive. $17 at amazon. Designed for lead-acid. I used this unit in my station until I found the GV-10.

http://www.sunforceproducts.com/product_details.php?PRODUCT_ID=56

73, Jim K9YC

On Tue,1/19/2016 12:23 PM, Thorpe, Jeffrey wrote:
I did that for a folding solar panel I purchased that put out 18V. A couple 
zeners dropped it to 15.3V. The panel doesn't have the juice for transmission, 
but fine for receive (or charging the batteries).

Jeff - kg7hdz

On Jan 18, 2016, at 16:21, Don Wilhelm <[email protected]> wrote:

John,

I would suggest that you put a diode in series with that supply - rated at 5 
amps.  That will reduce the voltage by the amount of the diode drop.
Running the KX3 (or any other device) above the specified maximum voltage is 
done at your own peril - it may work, but it taxes the regulators and other 
devices.

73,
Don W3FPR

______________________________________________________________


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to