Cant help thinking, that the charge to discharge "Efficiency" is probably no better than 
a good linear PSU, but you do I guess get the "Off grid" option for EMCOM work..

There ARE (RF)quiet SMPS's out there, but not priced in a way that will suit 
the average Ham's budget.   You get what you pay for.  Oh, and they tend to be 
large too, due to the filtering.

Quite honestly, for "Amateur" work, where the rig will usually spend most of 
it's life in RX, a linear PSU is just fine.   Plus, you can fix them when things fail.   
Try that with a modern well suppresed QRO SMPS!..

73.

Dave G0WBX.


~~~ Original message.

From: Marc Veeneman<[email protected]>
To:[email protected]
Cc:[email protected]
Subject: Re: [Elecraft] RFI on K3s
Message-ID:<[email protected]>
Content-Type: text/plain;       charset=us-ascii

My PowerWerx supply DOES generate those drifting noise spikes, ruining CW on 80 
meters for me.  I have yet to find a 13.8 volt switching supply that can 
provide 25 quiet amps.  I've gone entirely to batteries rather than use quiet 
but inefficient linear supplies.

 Now I only have SMPS noise when recharging the batteries.  So I leave that for 
non-hamming hours.  More testing is needed, but I did find one SMPS for LiFePO4 
batteries that seemed RFI free.  It's an Optimate brand product but only 
produces 5 amps.


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]