William,

The images will not be changed by the TX MON.
The resolution of the power display on the P3 will be increased by a factor of 10 if you change to the DCHF-200a - you can order one from Elecraft.

73,
Don W3FPR

On 7/2/2016 2:59 AM, [email protected] wrote:
I have a K3 100 Watt and i bought a P32 with VGA and TXmon, the TX Monitor
is 2 Kw.

I was thinking because of the fact that I am only working with 100 watt
would it be worth reducing the sensor to 200 Watt ??