On Sat, Aug 6, 2016 at 9:26 AM, Dave Fugleberg <[email protected]> wrote: > Still trying to sort out my transverter problem - see my first post on that > today. I have only the transverters connected to the K3. When I connect > power to the rig runner, the k3 tried to power on by itself and displays > 'turn on KAT 500'. I don't even have one, but I do have a P3, which is not > connected at this point. > I vaguely recall seeing that message when I first got my P3, and finding a > solution, I don't remember what it was.
See http://elecraft.365791.n2.nabble.com/New-K3-field-test-firmware-new-PSK63-mode-changes-related-to-KAT500-amp-K3-0-mini-td7593869.html Do you have something connected to AUX on the K3, that might be pulling down the AUXBUS line? 73, ~iain / N6ML ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected]