Hi, The VFO B display can show a wide variety of other information in addition to frequency by tapping DISP and rotating the VFO B knob. However, you cannot display alternate VFO B data while data or CW text decode is active.
This shows the total ampere-hours used since the value was last reset. It can be used to test batteries or estimate the remaining battery charge. Holding OFS/B/CLR when in the AMP HRS menu resets the amp-hours to 0. Cheers, Fred KE7X For all KE7X Elecraft books, see www.ke7x.com. ________________________________ From: Elecraft <[email protected]> on behalf of Richard Donner <[email protected]> Sent: Sunday, October 30, 2016 8:25 PM To: [email protected] Subject: [Elecraft] amp-hr reading from kx2 hi anyone know how to get the amp-hr usage on the kx2 ?? thanks Richard ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected] ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected]