I have been experiencing instability in drive to my K144XV/XV1/Beko
HLV-1000. I may have traced it down to the K3s' KXV3B board by creating
another transverter, XV2, with the same setup as XV1. I monitored the
output of XVTR OUT with an RF power meter and 50 dummy load. I did
observe a couple of occurrences of low power output that gradually came
back to requested power during an 8 minute test running WSTJx's MSK144.
The indication on the Beko watt meter is much more drastic of course.
If you have a similar issue, I would appreciate an email and what you
might have done to correct it. My intent is to re-seat the KXV3B board
and if that fails, then possibly replace it.
73s JIm, W4ATK