Hello everyone:
this time I have to come forward and confess with full exposure in broad day light. I made a terrible mistake!

My KPA100 tested beautifully untill I got to the 20A power supply test (page 45). As I turned on the K2 (#8 step) nothing happened. I checked and I had blown a fuse (the one that comes with the kit). I switched off everything and went back to figure 32 (page 38)...I had reversed the wires on j4 when I soldered them on the KPA100 board.

As I was taking my time to unsolder the cables, clean the pads etc. I thought I could turn on the K2 on its own (as before) with my low power supply and nothing else attached to it. Well here comes the suprise...I cannot turn on the K2 at all. I have the 13,0 volts allright, coming out of my small PS but nothing happens. What did I blow away?

J4 was plugged in P3, of course, when I blew the fuse.

Your comments and recommendations will be very much appreciated.

Thank you
73
Manuel Wilches
LU5OM
CT4IK
_______________________________________________
Elecraft mailing list
Post to: [email protected]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com