Nothing meaningful.
First, read AFV and for a couple of readings to set the reference. Then
go to dBV. dBV will then show you the difference in dB between the
current signal and the reference. On a dummy load it'll bobble around a
low value since it is just thermal noise and not a signal you are measuring.
73,
Lyle KK7P
On 5/18/17 3:37 PM, John Lally wrote:
What should the dBV reading on the kx3 when it is connected to a dummy load,
the agc is off, and no preamp?
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]