So, did you contact Elecraft support to discuss the issue? Grant/NQ5T
Sent from my iPhone > > While building the KPA500 I found that the ten mounting holes on the PA/LPF > module heatsink were not tapped deeply enough to accommodate the five 4-40 > 1/4" screws specified on page 22 of the assembly manual, nor the five 4-40 > 5/16" screws on page 24 of the manual. > I had to use the 4-40 3/16" screws in both cases. If I had used the screw > lengths as the manual specified, the module would be loose and insecurely > fastened to both the Z-bracket and the right side panel. ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected]