Ahh, that’s it!  

Dick




Sent from my iPhone

> On Jan 9, 2018, at 09:33, Paul Baldock <[email protected]> wrote:
> 
> I changed the Baud rate from 9600 to 38400 and now the POWER button works to 
> turn the amp on and off.
> 
> - Paul
> 
> 
> 
> 
> I am running KPA500 remote program. I am connected via RS232.
> 
> If the KPA500 is ON (at the back and at the front) then I can HOST and 
> CONNECT to the KPA500 and control all functions. When I press the POWER 
> button on the KPA500 remote program the KPA500 correctly turns off. However, 
> when I press the remote POWER button again the KPA500 does not turn back on. 
> It seems that the KPA500 RS232 port is not active when the KP500 is not ON.  
> Is this correct? If so how do I turn the power on remotely from the PC?
> 
> Thanks
> 
> - Paul
> 
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[email protected]
> 
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to [email protected]