Don

Was fairly certain that units were used incorrect but ya' never know so appreciate confirmation.

Wanting to get linearity test ready so now I know what is needed to set up.  I always want to monitor a new amp and the inclusion of this output allows that.

Now I do have one other "assumption" and that is the coupler is before the internal ATU so it is always working with a 50 ohm load, hopefully that is correct.

73

Dave K5MWR


On 3/23/2018 10:23 AM, Don Wilhelm wrote:
David,

It is just a coupler - nothing else makes sense for that use, so your -60dB assumption is correct.  Yes, it is relative to the output, so dBm is not the proper designation.

73,
Don W3FPR

On 3/23/2018 10:09 AM, David Box wrote:
I am trying to get ready for delivery of the KPA1500 and have become confused about the information available for the TX Sample port.

The only information I can find states that this is a low-level signal of -60dBm but dBm is a measure of absolute power which would put this signal at 1 nanowatt.

My first thought is that this is a typo and meant to show that the signal level on the port is -60dB with respect to output but need some verification.



______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to