Hi Steve,

When plugging in the large 50V power cables between the power supply and rf 
deck, make sure they are pushed in firmly with -two- distinct insertion clicks. 
After feeling the first click, push them in further for the second click.

We are finding some customers mistakenly think they are fully inserted after 
just the first click, which can lead to intermittent 50 V to the amp. 

If you still have problems after checking this, please contact 
[email protected] so we can help you resolve it.

73,
Eric
elecraft.com
_..._

> On Jun 3, 2018, at 6:09 AM, Steve <[email protected]> wrote:
> 
> Turned on #121 tonight. Keyed K3 with 15 Watts. Amp immediately went into 
> hard fault mode showing ‘50 VOLTS: 4.5 volts’ recycled and relayed. Immediate 
> hard fault showing ‘50 VOLTS: 2.5 volts’. Next recycle fault shows ‘50 VOLTS: 
> 2.1 volts’
> 
> Sounds ominous. Anyone have any ideas?
> 
> 73
> Steve AA4V 
> 
> 
> Sent from my I-Phone
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[email protected]
> 
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
> Message delivered to [email protected]
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to