I am using my KX3 as a WSPR beacon at 500mw with a Arduino based controller 
which provides GPS time sync, WSPR data, and audio.  Currently I am running 
mono band at 1 two minute transmit cycle per 10 minute time block.  Now I want 
to add KX3 band switching to my controller and increase my T/R duty cycle.  
Watching the PA.I current I see that my current 2 minute ON 8 minute OFF cycle 
shows a 30c ON – 46c OFF temp range.  Running a 2 minute ON 2 minute OFF cycle 
shows a stabilized 36c – 49c range after about 5 ON/OFF cycles, and running 
continuous transmit cycles stabilizes at 48c – 53c after 6 cycles.  So based on 
these 3 duty cycles I see a 16c, 13c, and a 5c temperature rise.  The 2 on/8 
off has the lowest max temp but the widest temp range, the continuous transmit 
has the highest max temp but the lowest range.  My plan would be to have my 
controller switch the KX3 through 5 bands transmitting the 1 minute 53 seconds 
on a band and switching to the next band during the 7 second opening.



I have done extended temperature calibration with the XG50 so frequency 
stability should not be a issue.



My question is, 53c (127f) is hot, are there any thermo stress issues to the PA 
or the KX3 in general with running any of these three duty cycles?  Obviously I 
don’t want to damage my KX3.



Tnx

George

WD0AKZ


---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to