For the station bonding jumpers, #10 AWG auto primary wire with a ring terminal attached is very adequate.   Easy to work with, inexpensive, does the job,  and makes for a clean installation. Personally, I crimp {mechanical connection}  and solder {electrical connection} my ring terminals on the jumpers.

73

Bob, K4TAX


On 10/12/2018 4:57 PM, Jim Brown wrote:
On 10/12/2018 2:32 PM, Edward R Cole wrote:
Probably using braid or multi-strand wire would make it easier.

Yes, but NEVER used braid exposed to moisture.

73, Jim K9YC