My new K2/100 is working well, so I decided to do a complete realignment and button it up.
I set up the reference oscillator using Spectrogram and EA3ADV's method. Using 10MHz WWV (and a couple of iterations), I managed to get the frequency to read within 10Hz on 10MHz WWV and 5Mhz WWV and within 10-20Hz on 15MHz WWV (all higher in frequency). However, 20Mhz WWV is off by 80-90Hz lower in frequency - the direction of the error is as expected, but not its magnitude. I would expect the error to increase as the frequency increases, but this seems like a lot. Is this another "Don't worry, be happy" situation, or should I look for a problem? Also, the temperature of the rig and room do affect this! With the lid off, I put a towel over the open top for about an hour, then removed it and ~15 minutes later, the dial had drifted about 20Hz. Thanks again! 73, Jim KO5V ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [email protected]

