Marv,
Are you using computer control of the K3S and power on the computer at
nearly the same time as the K3S? If you have the PTT-KEY menu set to
anything other than Off - Off, that can occur as the computer tests the
com ports.
Other than that, the K3S is detecting a key, paddle, or PTT closure when
it is powered up. You just have to find out which one. Unplug all of
them and plug them in one at a time (powering on after each one is
plugged) to reveal which one is causing the error.
Don't forget the microphone jack.
73,
Don W3FPR
On 12/24/2018 3:08 PM, [email protected] wrote:
This ERR KEY message as show up on my k3S displayed in the Sub Receiver
display area. Any ideas on how to get rid of it?
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]