Don Wilhelm wrote: > Unless there is something wrong with your KSB2, adjusting the carrier > balance pot on the SSB board will yield good carrier suppression. [...] > If you do not have a 'scope, an RF Probe and DMM may be used, but you will > have to adjust slowly to determine the minimum because the response time of > the DMM will be slower than the 'scope voltage indication.
This is what I did, but I found the null to be VERY VERY tight, the pot had to be in exactly the right place otherwise I had quite a strong carrier. I wouldn't be surprised if I've since knocked it and have too strong a carrier myself. Is the carrier balance pot supposed to be quite so sensitive, or have me and perhaps SM0YQC built something wrong that makes it so tricky to set? -- "Nosey" Nick Waterman, G7RZQ, K2 #5209. use Std::Disclaimer; [EMAIL PROTECTED] IBM: Intriguingly Blue Motif _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com