This is an issue I have been dealing with for some time now and the troubleshooting process has been complex so I will try to be specific about my questions. Bear with me as I summarize the issue.
My K2/KPA100 performs a complete power reset when TUNE has been activated for about 10 seconds. It indicates Hi Cur at that point. The radio has to be on for approximately 2 hours before it exhibits this behavior. This problem originally occurred in 2015. Don Wilhelm helped me troubleshoot it and I thought a solution had been found. The problem showed up again in 2018 and Don worked with me extensively to attempt to resolve it to no avail. Don finally threw in the towel on email troubleshooting and suggested I try replacing components in suspect circuits which I have done. Note that I have probably put in 100+ hours on this effort. We narrowed the problem down to something in the SWR Bridge or the LPF since it appears that the K2 is calling for more power than it can deliver increasing the current until it resets. With that very brief summary in place I will now ask some specific questions which I hope will be picked up on by someone at Elecraft. NOTE: DURING ALL THE TESTING THE KPA100 IS CONNECTED BUT WITH POWER SUPPLIED THROUGH THE BASE K2 CONNECTOR. I have measured the increase in current in TUNE when the Hi Cur event has occurred. I broke the 12V supply circuit to the base K2 PA and associated components to measure the current. During normal TUNE the current is 660mA. During the Hi Cur event the current is 1.9A - an increase of 1.2A. The current shown on the K2 display is 4A total. 1. What is the actual reset mechanism? I thought the re-settable fuse would not trip until 5A was drawn. If it is re-setting, why at 4A? 2. Why is there a 10 sec delay from initiation of TUNE until the K2 resets? 3. Is there some other mechanism for reset (in the firmware?) in the K2? 4. I have replaced every active component in the SWR Bridge including twice replacing the D16 & D17 diodes. I have removed and examined T4. What other components should I look at replacing? This is assuming, of course, that the problem is in the Bridge. 5. Is there something else that needs to be examined? Although I can't imagine what hasn't been examined during the troubleshooting by Don and myself. 6. A basic question - why is there a 2 hour period of power on before TUNE causes a reset? Believe me I have examined this one over and over. I don't expect an answer - just wanted to throw it out there. NOTE: I HAVE PERFORMED ALL UPGRADES DURING THIS ENTIRE PROCESS INCLUDING THE BASE PA UPGRADE. NOTE: IF ANYONE WANTS TO TAKE THE TIME TO READ IT, I HAVE COMPILED AND EDITED ALL OF OUR EMAILS INTO A MORE READABLE DOCUMENT. I REFUSE TO LET THIS THING BEAT ME! THERE HAS TO BE A SOLUTION TO THIS! Thanks for reading. 73, Jim WA4YWM -- Sent from: http://elecraft.365791.n2.nabble.com/ ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html