Tried a 10x scope probe and that did the trick. Thank You!. Mark
On Sun, Apr 21, 2019 at 5:48 PM Don Wilhelm <[email protected]> wrote: > Mark, > > I am not talking about the 10x/1x sensitivity scaling of your frequency > counter itself. > I am referring to the capacitance of the probe itself. You should be > using a 10x 'scope probe which has a low capacity and will not load the > PLL Reference circuit. > > 73, > Don W3FPR > > On 4/21/2019 1:07 PM, Mark Yergin wrote: > > BNC with mini test clips. I can switch in 10x (or 1x) on the FC but > > that doesn't make any difference. > > > > FC is a BK Precision 1823A. > > > > > > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html