----- Forwarded Message ----- From: Mike Streeter <wm...@yahoo.com>To: 
elecraft@mailman.qth.net <elecraft@mailman.qth.net>Sent: ‎Tuesday‎, ‎April‎ 
‎30‎, ‎2019‎ ‎02‎:‎50‎:‎12‎ ‎PM‎ ‎CDTSubject: KPA 500 HV Problem.
 My KPA 500 has been running ok for several years on 120 Volts. Today I turned 
it off on the back , unplugged it and opened the top because I thought I might 
need to change the voltage tap. I did not need to change it. I replaced the top 
cover, plugged it in and turned it on at the back. All ok, but when I turned it 
on with the front panel button the HV reads .1 in standby. If I tap OPER it 
shows a hard fault and "270V error" .The Manual says this is a 270V supply 
failure and to recycle the mains power KPA 500 after it is corrected. I tried 
recycling the power but still faults. I don't have any 270V power from the 
mains, if I did it would be 240ish, not 270. The fuse block on the back is set 
to 115V.Any advice would be welcome.Mike, WM5DX.
   
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to