Just got a repaired KPA-500 PA/LPF module from Elecraft and installed it in my KPA-500 Amp. I carefully (I thought) reassembled everything. When I powered-up the unit and tapped "HV" I get numbers between 9 and 11 volts (expecting ~ 65 or 70 Volts). I know this is not right. I double-checked the 270V line to the PA module and the top cover interlock. Surely I am doing something stupid.

Any ideas?

73,

Tom, KG3V


--
Get on the Air and make some noise
Ham Blog at WWW.KG3V.COM


---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus