Assuming the utility uses the ST command to set each band in turn then I suspect the utility fails to set all bands because the test for the first band being set correctly fails due to rounding errors. Once the test fails I suspect no attempt is made to set the other bands.
ST01K1.80; followed by ST01K; returns 1.80 ST01K1.50; followed by ST01K; returns 1.50 but ST01K1.60; followed by ST01K; returns 1.59 It does seem to be possible to set all bands to 1.59 by setting each individually to 1.60 using the STbbK command. 73, Andy, k3wyc ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html