Assuming the utility uses the ST command to set each band in turn then I 
suspect the utility fails to set all bands because the test for the first band 
being set correctly fails due to rounding errors. Once the test fails I suspect 
no attempt is made to set the other bands.

ST01K1.80; followed by ST01K; returns 1.80

ST01K1.50; followed by ST01K; returns 1.50

but

ST01K1.60; followed by ST01K; returns 1.59


It does seem to be possible to set all bands to 1.59 by setting each 
individually to 1.60 using the STbbK command.