Since the basic K4 is direct sampling, I don't see there being a hardware
blanker. On the other hand, the "HD" will be superhet with crystal filtering.
Crystal filters delay and stretch noise pulses, making subsequent software
blanking less effective.
So, my first question is, will there be a hardware blanker ahead of the crystal
filtering and will there be some delay in the signal path to compensated for
time delays in the noise channel?
Second, with there be enough "smarts" in the blanking system so an operator
doesn't have to wade through 400+ settings?
Wes N7WS
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]