I'm trying to calibrate the KAT1 using an RF probe. Parameter Atu is set to CLP, and Out is set to 5.0 watts. Docs say that when I enter TUNE mode and watch the DMM's voltage with the probe on RF hot and ground, I should adjust WPM+/WPM- until I see 14 volts on the DMM.
I see 3.67 V and it doesn't change when I press WPM+/WPM-. The K1 display doesn't change either - in fact it stays at 0.1 watts (not 5). When I exit TUNE mode, the Out parameter has reverted back to 0.1 watts. Any ideas? _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com